Portable solid oxygen for home medical use can be considered, which is suitable for home safety, stable in solid state, non-explosive, long in storage time, and portable and portable. The oxygen concentration is above 99% of the standard medical standard, which is actually pure oxygen. There is no need to go through the formalities. Buy it home and use it directly.
Extended data:
Safety precautions for using medical oxygen
1, strictly abide by the operating rules, pay attention to the safety of oxygen use, and do a good job of "four precautions", that is, earthquake prevention, fire prevention, heat prevention and oil prevention.
2. When handling oxygen cylinders, avoid dumping and bumping to prevent explosion, because the oxygen in oxygen cylinders is injected at 14.7438+0 MPa, and the pressure is very high.
3, oxygen cylinders should be placed in the shade, fireworks and flammable items are strictly prohibited around the cylinder, at least 5m away from the furnace, heating1m. ..
4, oxygen meter and screw mouth don't oil, also can't use oil hand loading and unloading, lest cause combustion.
5, when using oxygen, should first adjust the oxygen flow, and then the application of intubation; When stopping using oxygen, unplug the pipe first, and then turn off the oxygen switch; When changing the oxygen flow in the middle, the oxygen tube should be separated from the oxygen suction tube first, and then connected after adjusting the oxygen flow. In order to avoid a large amount of gas suddenly rushing into the respiratory tract and damaging lung tissue due to wrong switch. ?
6, in the process of oxygen inhalation, should closely observe whether the patient's symptoms of hypoxia have improved, regularly measure the pulse, blood pressure, observe their mental state, skin color and temperature, breathing style, etc. ; You can also measure arterial blood gas analysis to judge the curative effect, so as to choose the appropriate oxygen concentration.
7. The oxygen in the oxygen cylinder cannot be exhausted. When the pointer of the pressure gauge drops to 0.5MPa, it cannot be used again to prevent dust from entering, and it will explode if it is inflated again. Collection and arrangement of medical education network.
8, patients with continuous nasal catheter oxygen inhalation, nasal catheter should be replaced more than 2 times a day, bilateral nostril intubation alternately, in order to reduce the stimulation of nasal mucosa, clear nasal secretions in time, in case of blocking the basic properties of medical oxygen.