1, check the electricity:
When checking the electricity of low-voltage line bracket, low-voltage electroscope should be used. If the high-voltage electroscope does not display, the low-voltage electroscope should be used for further electricity inspection. Operators should keep a safe distance from live wires and ensure that their heads are 30cm below the cross arm.
2. Lifting of tools and insulation shielding equipment:
Nylon lifting ropes should be used, and ensure that the lifting ropes are tied in a position that does not interfere with normal operation, and tied tightly to prevent falling off. At the same time, the lifting position of nylon rope should be determined according to the relationship between the standing position of the operator and the lower facilities. Nylon rope should be hung at a height that does not touch the ground to prevent the rope from winding on other facilities.
3, safety protection:
Managers and maintenance personnel should have relevant vocational training and skill requirements, strictly abide by the operating rules and safety operation specifications, do a good job in safety protection, and ensure personal safety and equipment safety during work.
4. Environmental protection:
In the process of operation and maintenance management, we should pay attention to environmental protection and reduce power consumption and resource waste. Use equipment and materials reasonably, optimize equipment configuration, reduce energy consumption and reduce environmental pollution.
5. Inter-departmental collaboration:
The operation and maintenance management of low-voltage distribution network needs the cooperation of many departments, and communication and coordination should be strengthened to ensure the smooth progress of the work.
6, should also implement the safety responsibility system.
Clarify the safety responsibilities of each post; Establish and improve the safety management system and formulate relevant safety management rules, regulations and procedures; Strengthen the investigation and rectification of potential safety hazards. In a word, we should pay attention to the safety of low-voltage distribution network and take corresponding measures to prevent it.
Safety protection measures in low-voltage distribution network;
1, insulation measures:
In low-voltage lines, the application of insulation equipment is one of the important measures to ensure safety. For example, the overhead pillars of low-voltage lines need to be covered with suitable insulating materials to prevent leakage and short circuit. Insulation materials should have high temperature resistance, voltage resistance and weather resistance to ensure good insulation effect.
2, grounding measures:
For low-voltage lines, correct grounding measures are also very important. By grounding, the current on the line can be introduced into the earth, reducing the risk of leakage current and harm to human body. Through reasonable grounding system design, the safety of workers can be effectively protected.
3. Safety warning signs:
The low-voltage distribution system should be provided with obvious safety warning signs, such as high-voltage warning signs and no-touch signs, to remind personnel to pay attention to safety.
4, protective equipment:
Low-voltage distribution workers should wear personal protective equipment that meets the standards, including insulating gloves, shoes, helmets and safety glasses. These devices can effectively protect the safety of staff.
5, operation authority management:
Low-voltage distribution system should be clear about the management of operation authority, and only trained and qualified personnel can carry out low-voltage distribution operation. This can avoid safety accidents caused by misoperation.
6, safety training and education:
Conduct necessary training and education for workers engaged in low-voltage power distribution, so that they can have relevant knowledge and skills and correctly use and operate low-voltage electrical equipment.
7, maintenance and cleaning:
The equipment of low-voltage distribution system should be maintained regularly, and the wires, cables and distribution equipment should be cleaned to ensure the normal operation of the equipment and avoid safety accidents caused by equipment aging.