Current location - Education and Training Encyclopedia - Education and training - Energy-saving design of electrical lighting for civil buildings in Yunnan Province?
Energy-saving design of electrical lighting for civil buildings in Yunnan Province?
The Design Standard for Energy Efficiency of Civil Buildings in Yunnan Province is compiled by Yunnan Antai Construction Drawing Design Document Review Center and Yunnan Design Institute as the chief editors, together with 7 units in the province. It is suitable for the energy-saving design of public buildings and residential buildings newly built, rebuilt and expanded in mild areas of our province. Among them, for the energy-saving design of electric lighting, what is the energy-saving design standard of civil buildings in Yunnan Province? The following is the introduction of energy-saving design of electrical lighting for civil buildings in Yunnan Province brought by the construction network for reference.

Electric lighting should use high light efficiency light source and adopt appropriate lighting methods.

Under the condition of meeting glare limitation and light distribution requirements, efficient lamps should be selected.

Lighting control shall meet the following requirements:

1, different areas, different uses, different use times and different natural lighting conditions should be controlled separately.

2. For the large space lighting design with clear division of work area and passage area, partition control mode should be adopted.

3. When there are two or more rows of lamps and lanterns in the room or place with large bay, the controlled lamps and lanterns parallel to the side windows should be used for group control.

4. Lighting of roads, squares, outdoor parking lots, scenic spots, courtyards and lawns should be controlled by light, time, program or interval grouping.

5. The landscape lighting of the building should be controlled centrally, and the dimming control scheme should be set in the middle of the night, using the control methods of turning on the lights at ordinary times, turning on the lights at ordinary festivals and turning on the lights at major festivals, and automatically controlling the time and photoelectricity according to the seasonal changes.

6. In addition to the elevator hall and fire emergency lighting of high-rise residential buildings (apartments), the lighting of public parts of residential buildings (apartments) should be controlled by energy-saving self-extinguishing switches.

For more information about bid writing and improving the winning rate, click on the bottom customer service for free consultation.