Current location - Education and Training Encyclopedia - Education and training - ? What are the fire safety instructions for high-rise buildings?
? What are the fire safety instructions for high-rise buildings?
Do you know the fire safety regulations of high-rise buildings? Let's study together.

Fire truck climbing operation site

According to clause 7.2. 1 in Code for Fire Protection Design of Buildings (GB 50016—2014 (version 2018)), the workplace where fire engines need to be continuously arranged in high-rise buildings should be at least1with a long side or peripheral length. The purpose of this is to ensure that the fire truck can get close to the building smoothly for rescue.

Skirt depth

In addition, the depth of the podium within this range shall not exceed 4m, so as to ensure that the fire truck has sufficient operating space.

spacing distance

For buildings with a building height of less than 50m, if it is difficult to arrange the fire truck climbing operation site continuously, it can be arranged at intervals, but the interval should not be greater than 30m, and the total length of the fire truck climbing operation site still needs to meet the requirements.