The layout of dance halls, video halls, nightclubs, karaoke halls (including restaurants with karaoke functions), recreation halls (including electronic recreation halls), saunas (excluding bathing parts), Internet cafes and other places of song and dance entertainment (excluding theaters and cinemas) shall meet the following requirements:
1 should not be arranged on the second floor or below;
2 It should be arranged in the first, second or third floor near the external wall in the first and second class fire-resistant buildings;
3 should not be arranged on both sides or at the end of the bag-like walkway;
4 If it is really necessary to arrange the basement, the height difference between the basement and the outdoor entrance should not be greater than10m; ;
5 When it is really necessary to arrange underground or above four floors, the construction area of a hall and room should not be greater than 200m2;;
6 Between halls and rooms, between rooms and other parts of the building, fireproof partition walls with a fire resistance limit of not less than 2.00 h and incombustible floors of 1.00h shall be used for separation. Doors set on the walls of halls and rooms and doors communicating with other parts of buildings shall adopt Class B fire doors.
You can open an internet cafe on the mezzanine. Article 5 of the Law on Illegal Fire Prevention: It is enough to have a building area permit, otherwise it will not work. This unauthorized mezzanine is illegal. It is necessary to draw drawings according to qualified design units-submit them to the fire department for review-issue audit opinions-modify the drawings according to the audit opinions-re-submit for approval-issue construction opinions-submit the original audit documents to the construction unit for archiving-project construction-commissioning-hand them over to Party A after completion-professional units for testing-issue test reports-submit them to the audit unit for acceptance-conduct on-site acceptance-issue qualified opinions.
What are the fire safety regulations for office buildings? Fire safety education and training system
First, the person in charge of fire safety will incorporate fire safety education and training into the annual fire work plan to provide funds and organizational guarantee for fire safety education and training;
Second, the fire safety manager formulates the annual fire safety education and training plan of the unit, and is responsible for organizing the publicity, education and training of fire control knowledge and skills among employees;
Third, according to the annual fire safety education and training plan, determine the training content and lecturers, and organize volunteer fire brigades to carry out fire fighting business theory study and fire fighting skills training;
Four, in strict accordance with the annual fire safety education and training plan, organize all personnel to participate in fire education and training.
Five, employees should be trained once every six months, new employees and new employees should be trained in fire safety, publicity and education should be recorded;
The following personnel shall receive special fire safety training:
(a) the person in charge of fire safety and the fire safety administrator of the unit;
(two) full-time, * * fire management personnel;
(3) the fire control room on duty and operating personnel;
(four) other personnel who should receive special training on fire safety in accordance with the regulations.
The personnel in Item (3) of the preceding paragraph shall hold relevant certificates.
Six, the unit should carry out regular fire safety publicity and education through various forms. Every employee should receive fire safety training at least once a year. Publicity, education and training should include:
(a) the relevant fire laws and regulations, fire safety system and operating rules to ensure fire safety;
(two) the fire risk and fire prevention measures of this unit and this post;
(three) the effectiveness of fire fighting facilities and the use of fire fighting equipment;
(four) the knowledge and skills of reporting fires, fighting initial fires and self-help and escape.
The unit shall organize new employees and employees entering new positions to conduct pre-job fire safety training.
Seven, the unit can carry out fire safety activities every year according to local conditions, such as the national "1 19" fire publicity day, fire publicity week, etc. , organize targeted fire prevention publicity and education activities.
Fire inspection system
First, the daily fire inspection, to determine the inspection personnel, content, location and frequency. The contents of the inspection shall include:
1, whether there is any violation in the use of fire and electricity;
2, exit, evacuation routes are clear, safety evacuation signs, emergency lighting are in good condition;
3, fire control facilities, equipment and fire safety signs is in place, complete;
4. Whether the normally closed fire door is closed and whether the articles stacked under the fire shutter affect the use;
5. On-the-job situation of personnel in key parts of fire safety;
6, other fire safety situation.
Two, fire inspectors should promptly correct violations, properly handle fire hazards, can not be disposed of on the spot, it should be reported immediately. When you find the first fire, you should immediately call the police and put it out in time.
Three, fire inspection shall fill in the inspection records, inspection personnel and their supervisors shall sign the inspection records.
Safety evacuation facilities management system
One, all units of the office building to ensure safe evacuation routes, exits, the following acts are strictly prohibited:
1, occupying the evacuation passage.
2. Install fences and other obstacles that affect evacuation on safety exits or evacuation passages.
3. Lock or block the safety exits during business and work, or only block or cover the fire safety evacuation with signs.
4. Other behaviors that affect safe evacuation.
Second, the property right unit of the office building or the entrusted management unit should ensure that the fire doors, evacuation signs, fire accident lighting and other evacuation fire-fighting facilities are complete and easy to use. Once damaged or lost, it should be repaired and replaced in time.
Which law stipulates that Internet cafes can be opened in residential areas? Article 77 of the Property Law: Owners shall not change their houses into business houses in violation of laws, regulations and management regulations. Owners who change their houses into business houses shall obtain the consent of interested owners in addition to observing laws, regulations and management regulations.
So you have to get the consent of your neighbors and other interested parties. As long as citizens are in a place and time that is not prohibited by law, they can do things that are not prohibited by law.
Which fire law stipulates that Internet cafes must be opened on commercial land 1? There is no provision in this fire protection law.
2. However, according to the fire protection law, it can only be used if it is qualified. If it is not opened on commercial land, the building will not be accepted by relevant departments, especially the construction department and planning department, so it is impossible to go through fire control procedures.
Does the fire protection law require office buildings? Of course! And there are clear requirements!
The office building is an important place for fire control, and all facilities must meet the requirements of the fire control law! Otherwise, it is necessary to rectify or even punish within a time limit!
20 15 whether the new fire protection law stipulates that there should be no laboratory in the office building depends on whether the simulated test questions before the test are reliable or not, and the answer is still not credible.
Go to the local personnel examination center to check the relevant notice, and the information of registered fire engineers can be found in the summary of vocational training and education network, which is very comprehensive.
Does the fire protection law stipulate that the company's administrative office building and staff dormitory can be in the same building, but the dormitory needs to have separate evacuation passages and stairs, and because it is a commercial complex building, it needs to be equipped with automatic alarm and automatic sprinkler system, with an area of more than 1500 or a total area of more than 3000 square meters?
How many chapters and 74 articles of the Fire Protection Law stipulate seven chapters and 74 articles.
fire protection law
catalogue
Chapter I General Principles
Chapter II Fire Prevention
Chapter III Fire Control Organization
Chapter IV Fire Fighting
Chapter V Supervision and Inspection
Chapter VI Legal Liability
Chapter VII Supplementary Provisions
Article 74 This Law shall come into force as of May 6, 2009.