Current location - Education and Training Encyclopedia - Graduation thesis - Instructions for submission of industrial and mining automation
Instructions for submission of industrial and mining automation
This journal has joined CNKI China Journal Network, CNKI China Academic Journal (CD-ROM Edition), CNKI China Academic Journal Comprehensive Evaluation Database Source Journal and CNKI China Science Citation Database Source Journal. According to the People's Republic of China (PRC) and the General Administration of Press and Publication 17 "Notice on Printing and Distributing the Data Specification for Retrieval and Evaluation of Academic Journals in China (CD-ROM Edition)", combined with the problems existing in previous submissions and the operation practice of this journal, the following requirements are put forward for submission:

1. As the online publication of China Academic Journal (CD-ROM Edition) and China Journal, the author's remuneration is paid in one lump sum, and the remuneration standard is 30 ~ 70 yuan per thousand words. If the author doesn't agree with the article going online, please indicate it in the submission, and the editorial department will handle it appropriately.

Two, the manuscript should be highly scientific and practical, the content is true and accurate, there are new experiences and opinions, and have reference value for practical work. Words should be concise, logical and standardized. Comprehensive and theoretical articles should not exceed 6000 words, other articles should be controlled within 4000 words (including the layout occupied by charts), and the title should not exceed 20 words.

Third, the author and unit: the names of Chinese and English authors should be the same, and the unit should be written to the second level. Examples are as follows:

Research on new intelligent infrared gas absorption sensor for mine 1, Zhao Saiguo 2, Wang Rulin 1 (1. School of Electromechanical and Information Engineering, China University of Mining and Technology (Beijing Campus), Beijing100083; 2. 25th Research Institute of China Aerospace Second Research Institute, Beijing 100854) Research on new intelligent absorption gas sensor for mine-Wei 1,-Guo 2,-Lin 1( 1). CUMT Beijing Campus School of Mechanical and Electronic Information Engineering. China Beijing 100083. 2. Twenty-fifth Institute of China Aerospace Second Academy, Beijing 100854, China)

4. Please give a Chinese abstract of 100 ~ 300 Chinese characters in your submission. Abstract is a short article, which describes the content of the document concisely and accurately, without comments or supplementary explanations. There are two basic writing methods: reportorial summary and indicative summary. A reportable summary is a concise summary (also called introduction), which indicates the subject scope and content outline of the document. Indicative summary is a concise summary showing the theme of the document and the nature and level of its achievements. In between is the report/indicative summary, that is, the part of the document with high information value is expressed in the form of report summary, and the rest is expressed in the form of indicative summary. General scientific papers should be written as report summaries as far as possible, while comprehensive, informative or critical articles can be written as indicative or report/indicative summaries. The contents of reportage abstracts include the purpose, process and methods, contents, research results and conclusions. Specific methods, data indicators and other specific results and conclusions must be given. Suggested format: for …, based on/according to …, explore/introduce/adopt/put forward …, study …, and the results show that …

5. Please give 3 ~ 8 keywords that can reflect the main content of the document and have strong universality in the manuscript. First of all, we should select the standardized words (called narrative words or subject words) listed in the Chinese Thesaurus, MeSH and other tables. For those new terms that reflect new fields and disciplines but are not recorded in the list of disciplines, they can also be marked with non-standard free words. However, in order to emphasize the comprehensiveness of the theme of the document, the key words must not be written into a phrase, and the content is "comprehensive".

Six, the manuscript should be accompanied by the title, author's name, unit name, abstract, keywords and other English translations. The English abstract must correspond to the Chinese abstract. Generally, the passive voice is used as much as possible, and the results and conclusions are in the present tense to ensure the accuracy of professional vocabulary translation (refer to professional dictionaries if necessary). The suggested format is: "... described/investigated/studied based on ... proposed/proposed.

7. The introduction briefly introduces the background of the topic, the history and present situation of previous studies in related fields, and the author's writing intention and analysis basis, including the pursuit goal, research scope and the choice of theoretical and technical schemes. If more technical terms or abbreviations are used in the text, it is best to define the description in the introduction first.

8. If the contribution is a paper of a fund project, a national key science and technology project or a provincial science and technology progress award project, please provide the name and number of the fund project, and send a copy of the approval or certificate with the submission, and the manuscript will be published first.

Nine, the chart should be clear and standardized. The drawing shall have the drawing name and serial number; The form should have a title and a serial number. The formula should be correct, the derivation process should be rigorous, the data should be accurate and reliable, and the writing should be correct. The quantities, units and symbols used shall conform to the relevant national standards, and the symbols of quantities appearing for the first time shall be endowed with physical meanings. The case of the quantity symbol and the upper and lower corner marks shall be clearly marked. Symbol constants are orthographic, variables are italicized, and units are orthographic. The subscripts of quantity symbols are still variables or italics, and if they are explanatory texts, they are normal. Matrix, vector and vector are italicized in black. In addition, the case and italics of symbols must be consistent throughout the text.

10. Conclusion Based on the phenomena, data and analysis obtained from the experiment or investigation in this paper, the following problems should be pointed out completely, accurately and concisely: (1) The principle and universality revealed by the results obtained from the investigation or experiment of the research object; ⑵ Whether there are any anomalies found in the research or problems that are difficult to explain and solve in this paper; (3) Similarities and differences with previously published research work (including others or the author himself); ⑷ The significance and value of this paper in theory and application; 5. Suggestions for further research on this subject.

Eleven, the manuscript should be accompanied by a brief introduction of the author, including name, gender, date of birth, when to graduate from what college, degree, what work is currently engaged in, professional title, published articles, detailed mailing address and contact telephone number, postal code, e-mail, etc.

Twelve, the references should be listed at the end of the article, according to the order in which they appear in the article, corresponding to the serial number indicated in the article. Description format:

Journal [J]:[ serial number] author. Thesis title [J]. Name of publication, year of publication, volume (issue): start and end pages. Monograph [M]:[ serial number] author. Thesis title [M]. Version (the first version is not marked). Place of publication: publishing house, year of publication. Start page and end page. Prose. Year of publication. Dissertation [D]:[ serial number] Author's name. Thesis title [D]. Storage location: storage unit, year. Patent document [P]:[ serial number] patent owner. Patent name [P]. Patent country: patent number, publication date. International and national standards [S]:[ serial number] standard number.

Thirteen, please submit according to the requirements of this journal, the author keeps the manuscript, and the manuscript will not be rejected whether it is published or not. Please don't submit more than one manuscript.