Current location - Education and Training Encyclopedia - Graduation thesis - Wind load design steps?
Wind load design steps?
The standard value of wind load perpendicular to the surface of the object is calculated according to the following formula:

ωk=βzμsμzω0

(6. 1. 1)

formula

ωk- standard value of wind load, kn/m2;

Wind vibration coefficient of βz-z height;

μ s shape coefficient of wind load;

μ z-wind pressure height variation coefficient;

ω0- basic wind pressure value, kN/m2.

The basic wind pressure is to leave the ground on the local relatively empty and flat ground.

10 meter

Obtained by high statistics

30

Once a year.

10 minutes

Average maximum wind speed

υ0 (m/s) as the standard, press

ω 0 = υ 02/ 1600 to determine the wind pressure value.

Basic wind pressure shall not be less than

0.25 kn/m2.