What is the meaning of locking relay L in LS PLC? Is it equivalent to m auxiliary relay? What's the difference
L in LS PLC stands for communication connection relay: when installing the communication module, the L area is used for the symbol area of the communication module. It can provide information of communication module (O/S information, service information and label information). Data is stored in the operand-specific latch area 1. If the communication module is not used, the usage is the same as that of the auxiliary relay m.