Hospital fire safety knowledge test questions 1. Multiple choice questions 1. The fire protection publicity day in China is: (c)

A, September 1 1, b, 10, c, 1 1, d,11.

2. The pointer of dry powder fire extinguisher points to red, indicating: (B) A, high B, low C, normal.

3, according to statistics, more than 80% of people who died in the fire belong to (B).

A, directly burned to death; B, suffocated by smoke; C. jump off a building or frighten to death.

4. In case of fire in a relatively closed room (A)

A, you can't open doors and windows casually. B, you can only open the door C, you can only open the window.

5. In case of fire, there are three main directions for correct and safe evacuation, namely, running down to the ground, climbing up to the roof and (b).

A, hiding in the corner B, fleeing to the balcony C, drilling into the attic, kitchen and other places to take refuge.

6, fire caused by the fault of the actor, causing serious consequences, constitute (b)

A, arson b, arson c, dereliction of duty d, major liability accident crime.

7. The center temperature of cigarette butts can reach (C), which exceeds the ignition point of combustible materials such as cotton, hemp, wool fabric, paper and furniture. If cigarette butts are thrown around and come into contact with these combustibles, it is easy to cause burning and even fire.

a、 100-200℃ B、200-300℃ C、700-800℃

A, right b, wrong

8. It is irresponsible to throw away cigarette butts and light them two hours later. This statement (b)

A: Right B: Wrong.

9. The Fire Protection Law of People's Republic of China (PRC) stipulates that the fire protection work should follow the policy of (c), adhere to the principle of combining specialized agencies with the masses, and implement the fire safety responsibility system. A, who is in charge, who is responsible for B, prevention first, supplemented by elimination C, prevention first, combination of prevention and elimination.

10, the initial stage of the fire is the extinguishing stage (b). A, the most unfavorable B, the most favorable C, and the less favorable

1 1, check whether there is air leakage in gas appliance, and usually use (b) to find the air leakage point.

A, strike a match b, daub soapy water c, smell the smell

12, take appropriate measures to make the combustion go out due to lack of oxygen or oxygen. This method is called (a).

A, suffocation fire extinguishing method B, isolation fire extinguishing method C, cooling method

13, public security fire brigade put out (C) fire.

A Charges are only charged for the consumption of fire fighting equipment and chemicals. B charge all fees. C no charge.

14, when using a fire extinguisher to put out the fire, aim at the flame (C).

A, upper part b, middle part c and root part

15, stop reporting the fire alarm or make a false report about the fire alarm (c).

A, reeducation through labor b, take off his mobile phone c, warning, fine or detention for less than ten days.

16. The Fire Protection Law of People's Republic of China (PRC) stipulates that all units and (c) have the obligation to participate in organized fire fighting.

A, volunteer fireman b, individual c, adult citizen

17, the current fire telephone number in China is (b). a、9 1 1 B、 1 19 c、 1 10

18. When a fire breaks out in a public place, the on-site staff in the public place shall (c).

A, quickly evacuate b, rescue valuables c, organize and guide the evacuation of people present b, open doors and windows for ventilation c, and call the fire brigade 1 19.

19, when the oil pan is on fire, it is incorrect to use the following method (a) to put it out? A, put out the fire with water; b, cover the oil pan mouth with a pot cover; c, cover the fire blanket.

20, charged electrical equipment on fire can't use (b) fighting. A, haloalkane b, water c and dry powder

2 1. The evacuation door of the safety exit of public places of entertainment should be (b). A, bidirectional opening B, outward opening C, inward opening

22, storage of combustible materials warehouse management, must implement the relevant provisions of the state (a). A, fire safety b, material safety c, labor safety

23, public security firefighters in the process of fire fighting, should be (a). First, give priority to saving lives; B, give priority to the rescue of property; C, give priority to fire fighting.

Hospital fire safety knowledge examination questions II. Multiple choice questions 1. Regarding the use of dry powder fire extinguishers, the following statement is correct (BC).

A, outdoor use, should occupy the downwind b, unplug the safety pin before use.

C, put out the liquid fire, should be from the side of the flame, aimed at the root of the flame injection.

D is generally used for fire extinguishing of chemical reagents and precision instruments.

2, when using dry powder fire extinguisher to put out solid fire, it should be (ABCD)

A, the nozzle of the fire extinguisher is aimed at the most violent place, and B, the fire is strafed from left to right.

C, evenly spraying the mixture on the surface d of the combustion product, and sweeping until the fire is completely extinguished.

3. The following substances that cause Class A fires are (BC)

A, methanol b, original recording paper c, plush toy d and sodium

4. The fire fighting equipment of the building where the hotel is located is (AB).

A, dry powder fire extinguisher B, fire hydrant C, carbon dioxide fire extinguisher D, fire truck

5. The basic principles of fire prevention are: (ABCD)

A, control combustible b, isolate air c, eliminate fire source d and prevent the fire from spreading.

6. The Fire Protection Law of People's Republic of China (PRC) stipulates that all units and individuals have the obligation of (ABCD). A, maintain fire safety b, protect fire control facilities c, prevent fire d, report fire.

7. The development process of indoor fire can be divided into (B C D), (A), smoldering stage B, initial stage C, developing stage D and descending stage.

8. The way of heat transfer is (A C D). A, heat conduction b, thermal induction c, thermal convection d, thermal radiation

9, the cause of the electrical fire may be (ABCD). A, short circuit B, overload C, improper use of electric heating appliances D, leakage

10. If you are awakened by fire smoke while sleeping, the correct way is (BC) if conditions permit. A, quickly open the doors and windows; B, close the doors and windows of the combustion room before going out; C, cover your nose and mouth with a towel and quickly bend down to a safe area; D, hide under the bed and wait for the fire brigade to come to the rescue.

Hospital fire safety knowledge test questions III. True or false 1. After reporting the fire, send people to the door of the unit and the intersection of the street to wait for the fire truck, and lead the fire truck to the scene of the fire quickly. (? )

2. After the fire, if the escape route has been cut off, you should return indoors, close the doors and windows leading to the burning room, and splash the fire on the doors and windows to slow down the development. At the same time, open the window that is not threatened by fireworks and send out a distress signal. (? )

3. In case of fire, the basic correct emergency measures are: giving an alarm, evacuating people, and trying to put out the fire under safe conditions. (? )

4. Dry powder firearms are mainly used to extinguish the initial fires of petroleum and its products, combustible gas and electrical equipment. (? )

5. All fire extinguishers must be locked on fixed objects. (? )

6. In order to prevent explosion and fire caused by flammable gas accumulation, there should be good air circulation in the area where flammable liquids are stored and used. (? )

7. The fundamental measures for industrial fire prevention and explosion prevention are: try not to use and reduce combustible materials in production, and replace combustible and combustible materials with incombustible or refractory materials. (? )

8. The working distance between oxygen cylinder and acetylene cylinder should not be less than 4m. (? )

9. After the fire, if the escape route has been cut off, you should return indoors, close the doors and windows leading to the burning room, and splash water on the doors and windows to delay the development of the fire. At the same time, open the window that is not threatened by fireworks and send out a distress signal. (? )

10. "No fireworks? Signs usually appear in parts with high fire risk; Important places; Where materials are concentrated and fire losses are large; Where people are concentrated and fire casualties are heavy. (? )

1 1. Be careful not to smoke in these places, and use open flames at random in key fire prevention parts; Don't bring inflammable and explosive articles to the key parts of fire prevention; Strictly abide by the requirements of various safety signs and fire signs, abide by various fire safety systems, and obey the management responsibilities of fire security personnel; Discourage illegal personnel and stop illegal acts. Maintain the fire safety of key fire departments. (? )

12. foam extinguisher put out fires caused by gasoline, kerosene, diesel oil and wood. (? )

13. Don't throw away the waste cloth and cotton silk stained with oil in the workshop at will, but put them in the waste paper box. (? )

14.121kloc-0/Fire extinguishers are mainly used to put out fires such as oil, electrical appliances, precision instruments, meters and books. (? )15.121kloc-0/Check the total weight of fire extinguishers every six months. If it drops by one tenth, it must be filled and inflated. (? )

16. In case of fire, the basic correct emergency measures are to give an alarm, evacuate and try to put out the fire under safe conditions. (? )

17. In case of fire caused by electrical appliances, first turn off the power switch and cut off the power supply if possible; Use fine soil, sandy soil, carbon tetrachloride or l2ll firearms to extinguish the fire. (? )

18. The four main points of fire escape are smoke prevention; Decisively and quickly escape from the fire; Try to escape; Waiting for him to save. (? )

19. When calling a fire alarm, you should pay attention to find out the fire unit, detailed address, fire situation, what is on fire, whether there is explosion danger, whether someone is trapped, the telephone number used for alarm and the name of the alarm person. (? )

20. Dust is very harmful to human body, but it won't catch fire and explode. (? )

2 1. The three basic methods of fire fighting are isolation, suffocation and cooling. (? )

22. fire prevention? Six. No? The content is that smoking is not allowed in places where smoking is strictly prohibited; There must be a special person in charge of the production and living fire, and excessive use of fire is not allowed; Those who work overtime and stay at night should fulfill their duties and not leave their posts without permission; It is not allowed to install and use electrical equipment in violation of regulations; Teach children not to play with fire; All kinds of fire fighting equipment and tools are not allowed to be damaged or misappropriated. (? )

23. Fire prevention after work? Five don't go? The content is that you can't leave without changing shifts; Fire fighting equipment does not go until the fire source is extinguished; Electrical equipment does not operate without power failure; Clean up the combustible materials before going; If you find danger, don't report it, don't deal with it, and don't leave. (? )

24. Most fire deaths are caused by hypoxia, suffocation or poisoning. (? )

25. Fire prevention regulations in public places include smoking and using naked flames in public places; Do not bring fireworks, alcohol, gasoline and other inflammable and explosive dangerous goods into public places; Vehicles and articles are not close to each other, do not occupy fire-fighting facilities, do not block fire exits, do not misappropriate fire-fighting equipment, and do not damage fire hydrants, fire doors, fire alarms, fire sprinklers and other facilities; Learn to recognize safety signs and be familiar with safe passages; When a fire breaks out, it should obey the unified command of the management personnel in public places and evacuate to a safe place in an orderly manner. (? )

26. The fire caused by electric welding includes flying sparks, particles of molten metal and slag, and flammable materials and flammable gases near the welding site are burning to cause fire; The electric welding machine cord is dragged for a long time, causing insulation damage, short circuit and fire, or the electric welding circuit is misplaced, causing fire; The insulation of the welding machine itself or the power cord is damaged, causing fire due to short circuit and heating. (? )

27. Electrical fire protection? 12 1 1 ",dry powder fire extinguishers or carbon dioxide fire extinguishers have good effects, because the extinguishing agents of these three extinguishers have good insulation performance, and there will be no electric shock and personal injury accidents. (? )

28. In order to prevent fire, no-stopping signs should be set up in conspicuous places in the factory. (? )

29. After the fire, conduct a comprehensive and detailed inspection of the fire site, eliminate residual fire and smoldering, eliminate dangerous situations and hidden dangers, and prevent recurrence. (? )

30. In the production environment of enterprises, the main measures to do a good job in fire prevention are: establishing and improving fire prevention systems and organizations; Strengthen publicity, education and technical training; Strengthen the responsibility system of fire prevention inspection and eliminate unsafe factors; Conscientiously implement the fire prevention responsibility system; Equipped with appropriate and sufficient fire fighting equipment. (? )

3 1. When loading and unloading inflammable and explosive articles at night, naked lights are not allowed, and explosion-proof lights should be used. (? )

32. All inflammable and explosive factories and warehouses are fire-forbidden areas. No-fire signs should be set up in all no-fire areas. (? )

33. To control and eliminate the initial fire in time, we mainly rely on the public security fire brigade. (? )

34. When the smoke is thick, trapped people should use wet towels to block their noses and mouths, and walk or crawl through the smoking area in a low posture. (? )

35. A unit in the absence of a hot work permit, the leader instructed workers to carry out open fire operations, resulting in serious fire consequences, and the leader was criminally punished for committing a major accident. )

36.? Do you understand? It refers to knowing the danger of fire, measures to prevent fire, methods to extinguish fire and ways to escape. )