Current location - Education and Training Encyclopedia - Education and training - Ask the writing template of alkyd paint safety technical specification ~! !
Ask the writing template of alkyd paint safety technical specification ~! !
Material safety data sheet

Part I Identification of Chemicals and Enterprises

Chemical Chinese name: alkyd antirust paint for steel structure

Name of enterprise: Nanjing Changjiang Coatings Co., Ltd.

Address: Park West Road 157, Nanjing Chemical Industry Park.

Contact information of the enterprise: 025-58394888

emergency call

Shanghai Chemical Accident Emergency Consultation Service Tel: 02 1-62533429

Shanghai Chemical Safety Supervision Tel: 02 1-62679090

National chemical accident emergency consultation telephone: 0532-3889090

Part II Composition/Composition Information of Hazardous Substances

Chemical name mass fraction (%) CAS

Xylene 5- 15 1330-20-7

3P solvent oil 20-45 has no data.

The third part: risk overview.

Hazard category: flammable liquid with high flash point

Invasion route: inhalation, ingestion and percutaneous absorption.

Health hazards: Symptoms of mild poisoning include dizziness and headache.

Danger of explosion: This product is extremely flammable and irritating.

Part IV: First aid measures

Skin contact: Take off the contaminated clothes immediately and rinse the skin thoroughly with soapy water and clean water. See a doctor.

Eye contact: lift the eyelid immediately and rinse it thoroughly with plenty of flowing water or normal saline for at least 15 minutes. See a doctor.

Inhalation: leave the scene quickly and go to a place with fresh air. Keep the respiratory tract unobstructed. If you have difficulty breathing, give oxygen. If breathing stops, give artificial respiration immediately. See a doctor.

Intake: Give milk or gastric lavage and vegetable oil enema. See a doctor.

Part V: Fire Prevention Measures

Hazard characteristics: above its flash point, it is easy to explode in the explosion range. Sensitive to static electricity.

Harmful combustion products: carbon monoxide and carbon dioxide.

Fire extinguishing method and extinguishing agent: spray water to cool the container, and if possible, move the container from the fire to the open place. Extinguishing agent: foam, dry powder and carbon dioxide. Fire extinguishing with water is ineffective.

Part VI: Emergency treatment of leakage.

Emergency treatment: quickly evacuate the personnel in the leaked and polluted area to a safe area, isolate them, and strictly restrict access. Cut off the fire. It is recommended that emergency personnel wear self-contained positive pressure breathing apparatus and protective clothing. Cut off the leakage source as much as possible. Prevent it from flowing into confined spaces such as sewers and flood discharge ditches. Small amount of leakage: absorbed by activated carbon or other inert substances. You can also brush the emulsion made of incombustible dispersant, and dilute the emulsion and put it into the wastewater system. A large number of leaks: damming or digging holes to contain them. Cover with foam to suppress evaporation. Use explosion-proof pump to transfer it to tank car or special collector, and recycle it or transport it to waste disposal site for treatment.

Part VII: Operation, Disposal and Storage

Precautions for operation: close the operation and strengthen ventilation. Operators must be specially trained and strictly abide by the operating procedures. Operators are advised to wear filter gas masks (half masks), chemical safety glasses, gas permeable work clothes and rubber oil-resistant gloves. Stay away from kindling and heat sources, and smoking is strictly prohibited in the workplace. Use explosion-proof ventilation system and equipment. Prevent the steam in the workplace from leaking into the air. Avoid contact with oxidants. When filling, the flow rate should be controlled, and grounding devices should be provided to prevent static electricity accumulation. When handling, handle with care to prevent the packaging and containers from being damaged. Equipped with corresponding varieties and quantities of fire fighting equipment and leakage emergency treatment equipment. Empty containers may leave harmful substances behind.

Precautions for storage: Store in a cool and ventilated warehouse. Stay away from fire and heat sources. The reservoir temperature should not exceed 30℃. Keep the container sealed. Should be stored separately from oxidant, and should not be mixed. Adopt explosion-proof lighting and ventilation facilities. It is forbidden to use mechanical equipment and tools that are easy to generate sparks. The storage area should be equipped with emergency response equipment for leakage and suitable accommodation materials.

Part VIII: Contact Control/Personal Protection

Maximum allowable concentration: No data available.

Monitoring method: gas chromatography;

Engineering control: the production process is sealed and ventilation is strengthened.

Respiratory system protection: Wear a gas mask when the concentration in the air exceeds the standard. It is recommended to use self-contained breathing apparatus in emergency rescue or escape.

Eye protection: chemical safety glasses can be worn when exposed to high concentration steam.

Physical protection: wear corresponding protective clothing.

Hand protection: Wear chemical resistant gloves. A skin protective film can also be used.

Other protection: Smoking and eating are prohibited in the workplace. Take a shower and change clothes after work. Maintain good hygiene habits.

Part IX: Physical and Chemical Characteristics

Flash point (℃): 23

Ignition temperature (℃): 4 15 ~ 530.

Upper explosive limit% (volume/volume): 6.0

Lower explosive limit% (v/v): 1.3.

Solubility: insoluble in water, soluble in benzene, carbon disulfide, alcohol and fat.

Part X: Stability and Reactivity

Stability: stable at normal temperature and pressure.

Prohibited compound: strong oxidant

Conditions to avoid contact: heat, light, flammable materials and prohibited compounds.

Danger of aggregation: it won't happen.

Decomposition products: carbon monoxide and carbon dioxide.

Part XI: Toxicological data

Toxicological data: No data.

Irritant: Yes

Teratogenicity: none

Carcinogenicity: none

Part XII: Ecological data

Biodegradability: No data available.

Environmental toxicity: this substance may be harmful to the environment, so special attention should be paid to water bodies.

Part XIII: Waste Treatment

Characteristics of waste: containing organic solvents or harmful substances.

Disposal method of wastes: The disposal of wastes and empty containers shall comply with relevant laws and regulations. Incineration is recommended.

Precautions for disposal: Do not pour into sewers and water sources.

Part XIV: Transportation Information

Transportation shall comply with the following laws and regulations: Highway: ADR (European Agreement on the International Transport of Dangerous Goods by Road); Railway: International Rules for the Transport of Dangerous Goods by Railway; Transportation: IMDG (International Maritime Dangerous Goods Code).

Meet the following standards: dangerous goods classification and product name number GB 6944-2005;; ; General provisions for inspection, transportation and storage of coating products HG/T2458-93

Part XV: Regulatory Information

Comply with all domestic chemical safety management regulations.

Part XVI: Other Information

Other information

This material is based on our existing knowledge and national laws and regulations. However, the working conditions of users will be beyond our knowledge and control, and users have the responsibility to take necessary measures to comply with local rules and regulations.