④ The LED outside the door shows "Do not disturb" (red) and "Please clean up immediately" (green).
At the same time, designated network workstations (such as floor service stations) display "Do Not Disturb" and "Clean Room".
ü Weak current doorbell switch controls a weak current doorbell.
④ The doorbell switch is integrated on the display panel outside the door, and it will ring as soon as you ring the doorbell.
ü The "Do Not Disturb" display is interlocked with the doorbell; The "Do Not Disturb" display is interlocked with the "Please Clean" display.
3. 1. 1.2 Guest room entrance control panel
ü Includes three buttons of "Main", "Manufacture" and "Do Not Disturb".
ü The "main" switch can control the chandelier, painting lamp and bar lamp in the guest room corridor.
ü "Make" and "DND" are clean and do not disturb switches, and the LED on the display panel outside the control door displays "Do not disturb" (red) and "Clean now" (green).
ü If the "Do Not Disturb" control option is turned on, the "Do Not Disturb" display will remain after the main switch is pressed, and the "Do Not Disturb" display will also remain on the network computer.
ü The "Make" button can control the turn-on and turn-off of the "Please Clean" indicator (green light) on the display panel outside the guest room, and upload it to the network at the same time. When the guest presses the button and sends out the service instruction of "please clean up immediately", the network control program shows that the guest requests to clean up the room, and the guest presses the button again and cancels.
ü If the "please clean up" control option is turned on, after the guest leaves the room, the "please clean up the room" will still be displayed on the network computer.
ü The "Don't Disturb" button can control the turn-on and turn-off of the "Don't Disturb" indicator (red light) on the display panel outside the guest room, and interlock with the doorbell switch function. After the guest leaves the guest room, it will be automatically cancelled and uploaded to the network.
ü The "Do not disturb" control option is interlocked with the doorbell.
ü The "Do Not Disturb" control option is interlocked with the "Please Clean" control option; The "Make" button and the "Do Not Disturb" button are interlocked.
3. 1. 1.3 comprehensive control switch for toilet inner wall
The integrated control switch on the inner wall of the bathroom can control the switch of the lighting system and exhaust fan in the bathroom, the switch of the electric towel rack and the switch of the anti-fog mirror. The brightness of the light can be adjusted.
3. 1. 1.4 Fan temperature control switch
④ Air conditioning temperature and fan speed can be controlled manually;
④ Automatic control of solenoid valve switch;
ü The system can preset the working modes of air-conditioning fans in seven rooms, such as Room 0, Waiting for Rent, Reservation, Welcome, Sleeping at Night and Going Out, and allow the fan control parameters in various working modes to be remotely modified online through the designated computer on the hotel network (see 3.3 Special Description of Energy Saving Control Mode of Air-conditioning System in Beijing Oriental CB Energy Management Scheme for details).
3. 1. 1.5 lighting system
The system can preset four working modes of the room lighting system: welcome, suitable, sleeping and getting up at night, and allows the control parameters of the lighting system in various working modes to be modified remotely online through the designated computer on the hotel network;
3. 1. 1.6 (networking) central door lock
The central door lock of Beijing Oriental World Alliance network adopts PHLIPS Mifareone high-frequency card reading technology, which has stable and reliable performance. At the same time, the real-time room information management software system of Beijing Oriental CB includes special door lock control software. Through the networked intelligent control host and room control network, the door lock can be remotely managed online, the status of the room door and various unlocking signals can be monitored in real time, and the identity of the unlocking person (guest or hotel employee) can be determined. All monitoring data are kept in the database for reference at any time. This can bring many benefits. Mainly includes:
(4) real-time grasp the guest room personnel in and out of the state. Combined with the key card with identification function, the identity of people entering and leaving the guest room can be judged.
ü Simplify the customer registration process
ü The room card will be automatically cancelled when the account is settled.
④ Centralized cancellation of employee cards and guest cards.
(4) Real-time tracking of hotel employees' working status.
ü Network unified time service, all door locks are automatically synchronized.
ü Very detailed historical data of unrestricted access and restricted access provide higher room safety.
ü The network control program displays the opening and closing state of the guest room door in real time on the designated computer terminal.
(4) Alarm when the door is unlocked (after the door is unlocked for 2 minutes, the network control program will give an alarm on the designated computer terminal. You can set the alarm time of "door half open" in the room management software)
ü When the guest room door is opened with the key card, the corridor lights will automatically turn on, and the corridor lights will automatically turn off after a delay of 2 minutes. Guests can press the "porch light" switch to turn on the porch light again.
3. 1. 1.7 manned/unmanned state judgment
(4) whether there is a legal access card (access card) on the intelligent access control equipment can be used as the basis for whether there is anyone in the room.
The key card is the only legal access card. If the door key card is in the inserted state, it is judged as "someone"
3. 1. 1.8 Turn off the lighting system actively.
In order to save energy better, when the service personnel leave the room after cleaning the room, press and hold the "Please clean immediately" and "Do not disturb" switches for 3 seconds at the same time, and the system will automatically turn off the power of all controlled lighting appliances with a delay of 20 seconds.
* Note: According to the hotel management standards and management needs, there can be multiple "designated computers on the network" belonging to different hotel management and service departments. ü Real-time transmission of "please clean up" status to the computers of the room service center and the floor service station, with animation and music prompts; "Do not disturb" and "manned/unmanned" status are transmitted to room service center, floor service station, front desk and engineering computer in real time.
(4) guest and waiter identification function. Identify the guests or service personnel entering the guest room through the key card, and display and record it on the computer of the corresponding department in real time.
ü Call bearer service function. The caller's service signal is transmitted to the room service center computer in real time, with animation and music prompts.
ü The status of all guest rooms can be dynamically displayed in real time on the computer terminal of the main desk/control center in the form of pictures, and can be searched and switched at will.
ü On the computer terminal of the room service station on each floor, the status of all rooms on this floor can be dynamically displayed in real time by means of pictures, and can be retrieved and switched at will.
(4) When the guest sends a service demand instruction, the computer terminal of the corresponding department can automatically switch to the floor and guest room screen where the guest is located, and there are corresponding animation and music prompts for the service type.
(4) When there is equipment fault in the guest room, the fault status can be transmitted to the computer of the hotel engineering department in real time, and the fault type can be automatically identified. It is suggested that the important advantage of the engineering department to maintain the intelligent control system of Beijing Dongfang Shibang guest room is to greatly reduce the energy consumption of the hotel and effectively extend the service life of air conditioning system equipment without affecting the comfort of guests.
Generally speaking, the electricity consumption required for air conditioning system operation accounts for about 80% of the total electricity consumption of hotel rooms. The operation practice of all hotels adopting Beijing Oriental CB intelligent room control system shows that by using the energy management solutions and energy-saving technologies provided by Beijing Oriental CB and setting the air conditioning energy-saving mode scientifically and reasonably, the energy consumption can be greatly reduced (more than 25%) on the premise of ensuring the comfort of hotel guests.
The external environment temperature, seasonal changes and characteristics of the hotel and daily time changes have a direct impact on the energy-saving operation of the hotel air conditioning system.
Air conditioning systems generally have three control modes: cooling, heating and fresh air. Under different overall control modes, the air-conditioning energy-saving control modes set up and managed by the energy management system mainly include: suitable temperature mode, outdoor temperature mode, night sleep temperature mode, welcome mode, to be rented temperature mode and 0 room temperature mode:
ü "Suitable" temperature mode: it can be specified at will in the range of 22℃ ~ 24℃. Guests can manually adjust the room temperature and fan speed within a certain range by pressing the button on the digital thermostat of Beijing Oriental CB Network. If the target temperature manually adjusted by the guest deviates from the specified "suitable" temperature, the air conditioner will automatically return to the "suitable" temperature range specified by the system after running for a period of time (the length of time can be set).
For example, the hotel designated the suitable temperature of the summer room as 23℃ and the fan speed as "medium". After a guest enters the guest room, he sets the temperature of the guest room to 20℃ and the wind speed is "high" through the constant temperature button. 1 hour (this time can be set), in order to save energy and prevent guests from catching cold, the system will automatically jump the room temperature to 23℃ and the fan speed will be "medium". At this point, the display of the network digital thermostat also jumps to "23℃, medium".
ü "Outside" temperature mode: When the guest leaves the room temporarily by pulling out the key card for power on, or when the infrared/ultrasonic motion sensor in the room detects that there is no one in the room, the system will automatically raise or lower the appropriate temperature by 3℃ (cooling mode) or 3℃ (heating mode).
ü "Sleeping at night" temperature mode: The temperature setting is the same as the outdoor temperature mode. After nightfall, the system will automatically raise or lower the guest room temperature by 3℃ (in cooling mode) or 3℃ (in heating mode) according to the appropriate temperature, and automatically release it after dawn to enter the appropriate temperature mode. The system tentatively sets 1 1 pm to 7 am as the working time of the night sleep temperature mode, and the specific time can be adjusted according to the requirements of the hotel. In the future operation process, it can also be adjusted according to the actual situation such as seasonal changes.
ü "Rent-to-be" temperature mode: Add 5℃ (in cooling mode) or subtract 5℃ (in heating mode) on the basis of appropriate temperature to make the air conditioning system in a more economical and energy-saving state.
ü "0" room temperature mode: set the standard temperature of the vacant room in winter/summer, protect the room and the equipment in the room from the damage of bad temperature environment, and effectively shorten the pre-cooling (or preheating) time of the room.
ü "Welcome" mode: At the same time when the guests stay in the hotel, the system will automatically adjust the room air conditioner to high-speed operation for 5 minutes, so that the room can quickly reach the appropriate temperature. If the guest does not enter the guest room within 10 minutes, the temperature of the guest room will be automatically adjusted from the appropriate temperature to the guest exit temperature mode. When the guest leaves the hotel to check out, the room air conditioner automatically jumps to the temperature mode to be rented.
The energy management scheme provided by Beijing Dongfang Shibang guest room intelligent control system supports online programming. Your hotel can get information about the control software upgrade through official website, Beijing Oriental CB New Technology Development Co., Ltd., and download the upgraded energy-saving control software for free. You can also contact our software experts directly. They can adjust the settings of various control parameters or upgrade the control software according to the requirements of your hotel.