Current location - Education and Training Encyclopedia - Resume - Safety management regulations for unit maintenance?
Safety management regulations for unit maintenance?
In order to seriously implement the safety production policy of "safety first, prevention first and comprehensive treatment", effectively ensure personal and equipment safety, and make the overhaul of 1# unit safely and smoothly implemented and completed, the specific arrangements for the overhaul safety management of 1 # unit are as follows: 1. Personnel organization and division of labor 1, with Zhu Huaibai as the general manager. 2. Set up 1# unit maintenance site safety management team leader: Zhu Huaibai, deputy leader:, Zhang Qun, members: Wu Youliang, Zhang, Long, Xu Guogang, Zong, Jia Cunqiang, Liu Qiaoyong, Wang Hui, Wei Wu, Kun Wang, Zhang Xiaogao and Li Xianghong, totally 3 people. Division of labor and responsibilities (1) Yin # 65438 (2) During the overhaul of Zhang Qun, he mainly managed the internal affairs of the safety supervision department and the management of foreign construction teams, and assisted in overall management. (3) Zhang Shulei is mainly responsible for maintaining the electrical and all temporary power supplies at the site. (4) Yue Xiujun is mainly responsible for the safety management of the turbine and chemical maintenance site. (5) The supervisor is mainly responsible for the safety management of boiler, thermal engineering and fuel maintenance site. (6) Wu Youliang is fully responsible for the safety management of the maintenance site. (7) Zhang is responsible for operation safety management and maintenance isolation and operation management during maintenance. (8) Zhu Jun is responsible for the safety management of all maintenance items of # 1 unit steam turbine. (9) Xu Guogang is responsible for fuel-related maintenance projects and site management (10), and is responsible for the safety management of all maintenance projects of # 1 unit boilers. (1 1) Jia Cunqiang is responsible for the safety management of all electrical maintenance projects of # 1 unit. (12) Sliding Joe is responsible for the safety management of electrical operation during the maintenance of # 1 unit. (13) liuyong is responsible for the safety management of heat engine operation during the overhaul of # 1 unit. (14) During the maintenance, Shine Wong was responsible for the daily affairs of the Safety Supervision Department. (15) Wei Wu, Zhang and Li Xianghong are responsible for the maintenance during the overhaul, the operation management during the overhaul and the creation of a star team. II. Requirements for safety supervision 1. This overhaul implements the responsibility system. Who manages which aspect and is responsible for which aspect; 2. All safety supervisors are forbidden to work after drinking. Once found, it will be dealt with seriously. 3. Before maintenance, all safety supervisors should learn all maintenance procedures, various safety measures and on-site management and measures of the outsourcing team. 4. Every day 1 1: 30, a site safety liaison meeting will be held in the safety supervision department, and all site safety supervision personnel will attend. Discuss, arrange and implement related safety matters; And put forward safety precautions. 5, during the maintenance or on duty, the security officer should keep communication open, can find people at any time, to deal with special events. 6. All safety personnel shall participate in the three-level acceptance management of field equipment and be responsible for the acceptance work. 7, according to the maintenance progress, should be timely coordination, completes the safety measures. All safety supervisors should check the construction shelves and temporary power supply every day. 8, in the process of safety supervision and management, should pay attention to the data collection and sorting work, in order to write a summary report after maintenance. 9. If the safety supervisor fails to stop or deal with the violation in time, they will be punished together with the violator. Three. Management regulations for outsourced workers during maintenance 1. Three days before the overhaul, the engineering department is responsible for notifying the outsourcing team to go to the safety supervision department to handle the safety agreement. 2. The outsourcing team should set up the construction area according to the requirements of power plant location management, and each outsourcing team should have a maintenance safety fence with contact information and warning line. 3, there must be a contract, business license and construction certificate issued by the relevant departments; 4, the construction representative must have a representative qualification certificate issued by the enterprise legal person; 5, there must be a safety construction certificate; Construction resume and safety construction records in recent three years, the outsourcing team must be equipped with full-time security personnel; 6, safety construction technical quality (including the person in charge, engineering and technical personnel and workers) and special operations personnel to obtain evidence; 7, construction personnel and a copy with photos; 8. All registered construction personnel must sign employment contracts with the construction unit, and the construction unit must purchase personal accident insurance for the construction personnel. Registered construction personnel shall not be replaced at will, and shall not be an impostor; 9. The construction enterprise must equip the construction personnel with safety appliances and labor protection articles, otherwise Party A has the right to deduct from the contract amount; 10, according to national laws and regulations, the safety expenses must be fully paid. (used in this construction) 1 1. The outsourcing construction team must wear a pass when entering the construction site, and a special person must be appointed to take charge of the site. The person in charge of on-site construction must make safety technical disclosure to the construction personnel, and the construction site safety officer must wear a yellow armband. The construction site must be carried out in accordance with the requirements of fixed-point management, and smoking is strictly prohibited on the construction site. 12. The outsourcing team must be decorating. Four. Temporary power supply management regulations 1. The laying of temporary power supply lines must be uniform, without affecting the passage of personnel, equipment handling and installation; 2. Electrical equipment is connected with power supply by using leakage protection switch and socket. The leakage protection switch and leakage protector shall meet the specified requirements, and it is strictly prohibited for non-electricians to pull and connect randomly and dismantle the construction electricity facilities; 3, the protection of electrical equipment to zero should adopt parallel connection method, it is forbidden to series; 4, all kinds of distribution box installation and internal settings must comply with the relevant provisions, reliable electrical appliances in the box in good condition. Its selection and setting value conform to the regulations. All kinds of distribution boxes and switch boxes shall be complete and firm in appearance, rainproof and dustproof; Five, safety instruments management regulations 1. Safety instruments must meet the requirements of national and industrial laws, administrative regulations, rules, mandatory standards and technical specifications for safety instruments. 2. Welding machines for maintenance must have good insulation qualification labels; 3, seat belts should be used correctly, high and low, with suspension conditions, it is forbidden to hang on bamboo poles; 4. Before maintenance, each team should establish a management account of safety instruments, so that the accounts, cards and materials are consistent, and the test report and inspection records are complete. 5. Safety instruments shall be kept by designated personnel, and the custodian shall conduct regular daily inspection and maintenance. If it is found unqualified or exceeds the inspection period, it should be stored separately, and a sign that it is not allowed to be used should be made to stop using it. Personal safety instruments should be kept by themselves. It is forbidden to use safety instruments. 6. The helmet should be visually inspected before use. The components such as the helmet shell, the helmet hoop, the top lining, the chin strap, the back buckle (or the helmet hoop buckle) should be intact, and there should be a buffer space of 25 ~ 50 mm between the helmet shell and the top lining .. After wearing the helmet, screw the back buckle to the appropriate position (or adjust the helmet hoop buckle to the appropriate position) and lock the chin strap to prevent it from working. 7, scaffolding acceptance system, not acceptance shall not be used; 8, chain, wire rope and other lifting equipment before use should check whether its performance is good, and within the scope of its rated use, it is forbidden to overload use, lifting equipment shall not stay in the air for a long time, stay in the air for a short time, operators and commanders shall not leave their posts. 9. When lifting heavy objects at the maintenance site, the lifting point should be firm, and the center of gravity of the hoisted object should be grasped. Six, electric welding machine, oxygen, acetylene management regulations 1, oxygen bottles, acetylene bottles should have a fixed storage point, the safe distance between the two storage points should be greater than 8 meters, oxygen bottles, acetylene bottles can not be used indiscriminately; 2. When using acetylene bottles, a tempering generator must be installed; 3, welding machine shell, must have a good zero or grounding protection, power supply must be carried out by an electrician. The insulation resistance between the primary and secondary windings of the welder, between the windings and the iron core, and between the windings, leads and the shell shall be not less than 0.5 megohm; 4. The welding machine should be placed in a rain-proof and well-ventilated place. Flammable and explosive articles are not allowed to pile up at the welding site. When using electric welding machine, you must wear protective equipment according to regulations. 5. The length of the primary power cord of AC arc welding machine should not be less than 5 meters, and the length of the secondary cable of welding machine should not be greater than 30 meters; 6, electrode holder and wire must be well insulated and firmly connected, and gloves should be worn when replacing covered electrode. Work in a damp place. Should stand on the insulating rubber board or wooden board; 7, it is forbidden to welding on pressure vessels or pipelines, welding live equipment must first cut off the power supply. Welding containers or pipelines that have stored flammable, explosive and toxic substances must be cleaned first, and all orifices must be opened; 8, when welding in a closed metal container, the container must be reliable grounding, well ventilated, and should be supervised, it is forbidden to oxygen loss into the container. Vii. 1 Safety management regulations for star-rated teams during overhaul. According to the Standard and Assessment Methods for Star-rated Teams in Power Plants, the maintenance team is required to strengthen the construction of star-rated teams, and the overhaul site of # 1 unit is required to be inspected daily. 2. When entering the maintenance site of # 1 unit, you must wear safety protection articles correctly, fasten clothes and cuffs, wear safety helmet correctly and use qualified instruments. 3. The maintenance team should sort out all the contents of the maintenance work, make statistics and summary on the untreated defects in the operation of the unit, and incorporate them into this maintenance plan. Ensure that there is no omission or omission during the overhaul of # 1 unit. 4. Star-rated team assessors will check the team briefing every day. The "three exchanges" and "three evaluations" of the team pre-class meeting should be put in place. Before the shift, explain the location, content, scope, safety precautions, safety precautions, etc. A detailed description of each job, and a clear definition of the person in charge of each job and the members of the working group; When cooperating with other departments and teams, the scope of work, coordination between work, safety precautions and safety precautions must be made clear; For the relevant work of each working group in this class, we must clearly explain the cooperation mode and safety precautions, put forward targeted safety measures and precautions, and implement the responsible person. 5. The person in charge of the work and the licensor shall jointly go to the site to check and confirm the safety measures, and go through the formalities for the commencement permit at the site. The person in charge of the work shall organize all members of the working class to explain the work tasks, safety measures, dangerous points, control measures and matters needing attention, and sign after confirming the mastery. 6. When outsiders participate in the team maintenance work, the team must make safety technical disclosure on the work content, and strictly implement "one post and one disclosure". It must be signed by the discloser and the discloser (the team reserves the disclosure). 7. Temporary fences should be set up in the operation area of the maintenance construction site, and relevant warning signs and signs should be hung, which meet the relevant requirements of laws and regulations and have complete signs. After maintenance, all signs are restored to be complete and correct, and things are true. 8. The maintenance construction site should have a fixed layout, and the spare parts, materials, tools and instruments of the maintenance equipment should be placed in the positions specified in the fixed layout, so as to achieve "three in one", "three in one", "three out" and "three in one". During the maintenance, the civilized production at the site should be cleaned up in time, and after the maintenance, the site should be cleaned up, and the operator should check it to be qualified. 9.# 1 During the overhaul of the unit, the team should make danger prediction every day, and the star team assessor should evaluate the danger prediction every day. 10, # 1 During the overhaul of the unit, the assessor of the star-rated team will check the implementation of the working ticket to ensure that the qualified rate of the working ticket is 100% and the safety measures are in place. 1 1. Check whether each team earnestly implements the "three-level acceptance system" after maintenance and whether they carefully fill in the test and acceptance results records.

For more information about project/service/procurement bidding, and to improve the winning rate, please click on the bottom of official website Customer Service for free consultation:/#/? source=bdzd