1, power supply
Ensure sufficient power, use linear power supply as far as possible, and separate power supply for door lock and controller. The power supply should be installed as close as possible to electrical equipment to avoid interference and transmission loss.
Step 2 connect wires
It is divided into power line, communication line and signal line. Pay attention to the separation of strong and weak current when wiring, and the distance between the two tubes should be more than 20cm.
Power cord: the wire diameter is thick enough, and there are many wires.
Signal line and communication line: Five types of shielded twisted pair are used. Among them, the 485 bus must be connected by a pair of twisted pairs. It is recommended to use 4*0.5 four-core shielded wire when purchasing wires.
Matters needing attention
(1), the shielded wire shall not be used as the connecting wire for 0V voltage (power ground).
(2) Each shielding loop can only have one grounding terminal.
(3) When the shielded circuit cannot be grounded, the shielded wire can be connected to another shielded circuit of the network.
(4) The signals of each module must be connected together.
(5) If there is a breakpoint in the middle of the line, weld the breakpoint with a soldering iron and insulate it.
(6), don't put the network cable and AC power supply together.
(7) If the network connection exceeds 1000m, a repeater should be added. It can be extended after the repeater1000 m.
Location selection
(1) card reader: Do not install it on a metal object, and the distance between two card readers should not be less than 30cm. It is best to supply power through the controller. If the power supply of the card reader comes from the outside alone, please use a linear regulated power supply (transformer) to supply power to the card reader, and the DC negative electrode cannot be connected to the AC grounding terminal.
(2) Network card: The connection with the controller is hand in hand.
(3) Controller: without isolation, it is recommended to use the same power supply.
(4) Lock: When installing a magnetic lock, the lock body and the relay board must be closely combined, otherwise the suction is insufficient. Plug lock, if it is necessary to open the jack when installing the plug lock, pay attention to that the gap must be large enough and the depth must be deep enough for the locking tongue to be completely inserted. The locking bolt is not inserted completely, and the locking bolt jumps all the time after locking the door, or the working current is always very large, and the lock body heats up.
Second, the common faults and maintenance methods of access control system
1, valid card cannot open the door.
1. Check whether the electric lock is normal. Check the power supply or replace the electric lock.
2. Whether the lock tongue and lock are mechanical, repair mechanical failure or replace parts.
3. Check the indicator light on the control panel, and check whether the communication between the control panel and the module is normal, so as to troubleshoot.
4. Check whether the communication between the card reader and the module is normal, so as to troubleshoot.
5. Is the information day closing command set to adjust the opening time through software?
6. Does the operator initialize the access control system or reauthorize other commands through software?
2. Access control communication is blocked
1. Check whether the serial port is set incorrectly (determine the serial port used).
2. Check the access control communication bus for short circuit or open circuit (excluding short circuit and open circuit of communication lines).
3. Check whether communication chip 75 184 of RS485 communication card is damaged (replace communication chip 75 148).
4. The RS485 communication card is damaged (replace the RS485 communication card)
5. Check whether the crystal head of the network cable is ready, check whether the network cable is connected and ping the address of the access controller.
3. Unable to extract the access control record.
Empty the access controller and reload the time.
The door lock is always open.
1). The operator sets the access control status to normally open, or the controller is normally open for other reasons;
2). Controller failure;
Solution: Set the state of the door lock controller to normal. If the fault persists, replace the controller.
5. The 5.IC card cannot be read.
1.When the IC card is authorized, the card reading validity period has been set (it can be set to be valid for all-day card reading).
2. The entrance guard controller is abnormally hot (replace the entrance guard motherboard)
3. Access control read-write antenna (adjust fine-tuning capacitor to increase reading distance)
6. The communication between the computer and the controller is unstable.
1. Use unqualified signal lines or inferior signal lines;
2. The signal wire laying is not standardized, such as the signal wire and the power wire passing through the same tube.
Three, access control installation details, pipeline diagram, system diagram, electric lock installation diagram
Please click to enter a picture description.
Access control installation details
Please click to enter a picture description.
Please click to enter a picture description.
Please click to enter a picture description.
Three views of access control equipment installation
Please click to enter a picture description.
Please click to enter a picture description.
Please click to enter a picture description.
Summary of 49 lock faults in access control system
1, Q: Why is the electromagnetic lock loud when it closes the door?
A:
A. check whether the rubber washer is installed.
B. Check whether the iron plate ends and screws are too loose.
C. Check whether the distance between the magnetic lock body and the suction cup is appropriate.
Please click to enter a picture description.
2. Q: Why can't the iron plate suck firmly after the magnetic lock is used for a period of time?
A:
A. Check whether the "power and voltage" 1A/ 12V/24V output of the power supply is reduced.
B check whether there are foreign objects (such as dust, rust and foreign objects) on the surface of the magnet.
3. Q: Why does the magnetic lock iron plate often need to be adjusted?
A:
A. check whether the iron plate is nailed firmly.
B. check whether the iron plate is equipped with rubber pads.
C it is recommended that the customer apply "screw fixative" to the screws.
4. Q: What iron plate feels slightly shaken after being sucked, and the suction is insufficient?
A:
A. Check whether the main surface of the magnetic lock is completely adsorbed on the iron plate, and there are no foreign objects, or try to loosen the iron plate.
B. check whether the voltage and current are sufficient.
5. Q: Why is the magnetic lock delayed, but it doesn't work?
Answer: A. The "delay adjustment" of the magnetic lock starts timing after the power is turned on, not after the door is closed.
B the delay time of magnetic lock is 0, 3, 6 and 9 seconds. Let's see if the time is set to 9 seconds.
6. Q: Why is the red LED light slightly bright when the magnetic lock is energized?
Answer: Check whether the voltage is enough to meet the requirements of the electromagnetic lock (it should be 1A current/12V voltage).
7. Q: Why is the magnetic lock energized and attracted, but the red LED light is always on instead of green?
Answer: It may be that the inductive element of the magnetic lock is damaged and needs to be replaced.
8. Q: Why do you use a double-door magnetic lock, and it takes a while to absorb it?
A: The power consumption of the double-door magnetic lock is relatively high. Check whether the power supply is sufficient (whether the current and voltage required by the double-door electromagnetic lock are sufficient, or whether there is line loss).
9. Q: Why can't the magnetic lock work with the controller?
Answer: Check whether the "output" contact of the controller is correct.