Civil regulations only stipulate the number of sockets, but not the load of each socket. A few years ago, the designer's empirical data was 100w per socket.
2. Paragraph 9 of 10.8. 1 in Code for Electrical Design of Civil Buildings (JJ16-2008) stipulates that three-hole 15A sockets should be used for electric water heaters and cabinet air conditioners in houses. 15A socket can meet nearly 3kw air conditioning equipment.
3. Paragraph 3 of Article 6.5.2 of the Code for Residential Design (GB 50096- 1999 2003, 2003 Edition) stipulates that the air conditioning power socket, power socket and lighting of each residence should be designed separately; The kitchen power socket and the bathroom power socket should be provided with independent circuits;
Therefore, when designing the number of circuit sockets, the number of sockets should not exceed 10, and high-power equipment such as induction cookers and air conditioners should be designed in a separate way, and independent circuits should be set up.