First, the post conditions
Article 1. Drivers must be trained, pass the examination and hold relevant certificates.
Article 2 should be familiar with the relevant provisions of the "coal mine safety regulations", familiar with the general structure of mine ventilation, working principle, technical characteristics, performance of each part, power supply system and control circuit, as well as the use of ground air duct system and dampers, as well as the negative pressure of mine ventilation, and can operate independently.
Article 3 Drivers shall not have symptoms that hinder their work.
Second, the safety regulations
Article 4 No drinking before going to work, no sleeping at work, and no doing anything unrelated to your job. Strictly implement the succession system and the post responsibility system for each type of work, and abide by the relevant provisions of these operating procedures and the Coal Mine Safety Regulations.
Article 5. When the main ventilator can't stop, the standby ventilator must be started within 10 minutes and turned into normal operation.
6. When the mine needs anti-wind, the anti-wind operation must be completed within 10 minutes.
Article 7 the main ventilator driver should strictly abide by the following safety regulations and operating discipline:
1. The setting value of the protection device shall not be changed at will.
2. Insulating tools should be used when operating high-voltage electrical appliances, and the operations should be carried out in the prescribed order.
3. Assist the mechanic to check and maintain the equipment and do the daily maintenance of the equipment.
4. The air inlet door of the ground air duct should be locked.
5. In addition to emergency parking, it is forbidden to stop for no reason.
6. No fireworks and no open flames are allowed in the ventilated room and within 20 meters near it.
7. When opening and closing the air door, if two sets of mobile and manual devices are installed, the handle should be removed to avoid injury.
8. Fill in all kinds of records in time and truthfully, and do not lose them.
9. Tools and spare parts, etc. Should be placed neatly, equipment and indoor and outdoor hygiene should be improved.
10. Start, stop and operate the ventilator against the wind in strict accordance with the superior orders.
Third, the operation preparation
Article 8 the start of the ventilator, must get the permission of the competent superior driving command.
Article 9. Before starting the ventilator, the following inspections shall be conducted:
1. The amount of bearing lubricating oil is appropriate, the oil quality conforms to the regulations, and the oil ring is complete and flexible.
2. All fasteners and coupling covers are complete, and the fastening and transmission belt are moderately elastic and free from cracks.
3. The motor carbon brush is complete, the contact is good, and the slip ring is clean without burns;
4. Relay setting is qualified, and all safety devices are flexible and reliable.
5. Electrical equipment is well grounded.
6. All indicating instruments and protective devices are complete and reliable.
7. All starting switch handles are in the off position.
8. The power supply voltage meets the requirements of motor starting.
9. The air door is in good condition, and there is no sundries in the air duct.
10. 1 ~ 2 turns of manual rotation should be flexible, without jamming and abnormal phenomena.
Fourth, the operation sequence
Article 10 The main ventilator normally operates in the following order:
1. Start-up: after receiving the command to start the main ventilator, check whether each damper is in the correct state, operate the starting equipment, start the fan motor, complete the motor start-up, slowly open the damper leading to the underground, make each damper in the normal ventilation state, complete the fan start-up, and report to the mine dispatching or relevant departments.
2. Stop: after receiving the stop command → power off and stop → the fan motor stops running, and the relevant air doors are operated according to regulations → report to the mine dispatching or relevant departments.
Verbs (short for verb) operate normally.
1 1 to start operation:
1. Open and close the damper correctly. The axial flow fan should be started by opening the air door, and the air inlet door leading to the underground should be closed. At the same time, the air inlet door on the ground should be opened and supported firmly to prevent it from closing automatically when the ground wind is sucked.
2. The centrifugal fan can only be started by closing the air door, that is, the air door leading to the underground and the ground air inlet are closed.
3. When automatic and semi-automatic starting devices of magnetic stations are used, they should be operated according to the design instructions.
4. When starting the wound asynchronous motor manually with rheostat, the motor slip ring handle should be in the starting position, all resistors should be connected, and the starter handle should be in the "stop" position. When the starting current begins to fall back, gradually pull the handle and slowly remove the resistor until it is completely removed, the rotor is short-circuited and the motor enters the normal speed operation state.
5. When the squirrel-cage asynchronous motor is started with a reactor, the motor stator should be connected with all reactances before starting. After starting, when the starting current drops, all reactances should be removed manually (or automatically) immediately to make the motor run normally.
6. After asynchronous starting of synchronous motor, the excitation should be synchronized in time, which should not be too early. When the excitation regulation is excessive, the DC voltage and current should conform to the working curve of the excitation device used. The synchronous motor is allowed to start twice continuously. If the third startup is needed, it is necessary to find out the causes of the first two failures and the equipment status before deciding whether to start.
Article 12. After the ventilator is started, the air door operates:
1. axial fan: open the air door leading to the underground and close the ground air inlet door at the same time.
2. Centrifugal ventilator: Open the air door leading to the underground.
Article 13. Normal shutdown operation of main ventilator:
1. Received the shutdown order from the supervisor.
2. The power is out.
3. According to the stop command, decide whether to start the standby fan. If it is necessary to start the standby fan, it should be carried out according to the above normal operation requirements.
4. When the standby fan is not turned on, the wellhead explosion-proof door and related air doors should be opened to make full use of natural ventilation.
Article 14. The main ventilator should be checked in class:
1. The patrol inspection time is usually once every hour.
2. The main contents of the patrol inspection are:
(1) All rotating parts shall be free from abnormal sound and vibration;
(2) The bearing temperature shall not exceed the limit;
(3) The temperature rise of the motor shall not exceed the specified requirements;
(4) the instrument indicates normal;
(5) The motor current shall not exceed the rated value, and overload is strictly prohibited;
(6) The voltage should meet the requirements of the normal operation of the motor, otherwise it should be reported to the technical personnel in charge of the mine to decide whether to continue running.
3. Pay attention to check the negative pressure change at any time, and report to the mine dispatching department in time if any abnormal situation is found.
4. The problems found in the patrol inspection and the treatment process must be filled in the running log in time.
Article 15. Daily maintenance contents of main ventilator drivers:
1. Bearing lubrication:
(1) The sliding bearing should be replaced regularly according to the specified requirements, refueled in time during daily operation, and the required oil level should be maintained frequently;
(2) Rolling bearings should be lubricated with specified grease, and the oil amount should meet the specified requirements;
(3) It is forbidden to mix different oil numbers.
2. The standby ventilator must always be kept in good condition:
(1) rotates every 1 ~ 3 months, with the longest period not exceeding half a year;
(2) The standby ventilator that has been rotated for more than one month should be idling 1 time every month, and each time should be no less than 1 hour, so as to ensure that the standby ventilator is in good condition and can be put into operation within 10 minutes.
Six, special operation
Article 16 Emergency stop operation of main ventilator:
1. Direct power cut (high voltage circuit breaker first).
2. Immediately report to the mine operation department and the competent department.
3. According to the decision of the person in charge of mine technology, close and open the air door.
4. When the power supply loses pressure and stops automatically, pull down the circuit breaker first, then open the isolating switch, and immediately report to the mine dispatching room and the competent department, and then start it after troubleshooting or restoring normal power supply.
Article 17. When the main ventilator has one of the following circumstances, it is allowed to stop first and then report:
1. The main transmission parts have serious abnormal sound or vibration.
2. The motor runs in single phase or smokes and catches fire.
3. The air intake gate falls off and cannot be restored immediately.
4. Sudden power failure or shutdown caused by power failure, pull down the power switch of the computer room before reporting.
5. Other emergencies or failures.
Article 18: Anti-wind operation of main ventilator:
1. Anti-wind should be carried out under the direct command of the mine manager or chief engineer.
2. When the air duct is used to reverse the wind direction:
(1) Keep the ventilator running normally;
(2) Fix the explosion-proof door or explosion-proof cover firmly with the land lock;
(3) Operate the air door according to the instructions of the on-site commander to change the air flow direction.
3. When the reversing motor is used to reverse the wind direction:
(1) Stop the current fan operation;
(2) Fix the explosion-proof door (cover) firmly with the land lock, and keep the air door unchanged;
(3) After the motor stops, use the reversing device to reverse the starting motor;
(4) For the fan with fixed guide wing, directly reverse the start of the fan; for the fan with adjustable guide wing angle, first adjust the guide wing adjuster and change the guide wing angle. Then reverse the starting motor.
4. Other types of ventilators shall be carried out according to the requirements of the manual.
Article 19. When replacing the standby ventilator for idling test, it should be carried out according to the correct instructions of the on-site command.
Seven, the finishing touch
Article 20. Do a good job of fan operation record and duty log.
Article 2 1 will seriously explain the existing problems to the succession drivers.