20 17 personal summary of sewage treatment plant 1 g Qi Teng sewage treatment plant, with the care and guidance of leaders at all levels and the efforts and cooperation of all shift employees, has ensured the stable and up-to-standard operation of the sewage treatment plant. The report on 20 14 operation of Keqi Sewage Treatment Plant is as follows:
I. Completion of Energy Saving and Emission Reduction of Keqi Sewage Treatment Plant
Keqi Sewage Treatment Plant strictly follows the requirements of the company and its superior construction, environmental protection, finance, water conservancy, discipline inspection and other departments, strictly manages and makes unremitting efforts to ensure the stable operation of the sewage treatment plant. Keqi Sewage Treatment Plant treated 4.23 million tons of wastewater from the end of 20 14 to the end of February, with a treatment load rate of 77.3% and an average daily treatment capacity of1.160,000 tons. The average concentration of influent ammonia nitrogen is 58.2mg/L, and the average concentration of effluent ammonia nitrogen is 24.8mg/L, realizing ammonia nitrogen reduction 15 1.3 tons; The effluent indexes all reach the national second-class standard of urban sewage discharge.
The online monitoring data of Ketengqi Sewage Treatment Plant is connected with the monitoring platform of Chifeng Environmental Protection Bureau in real time, and materials such as daily, weekly, monthly, quarterly and annual verification are submitted to the superior environmental protection department, construction department and development and reform department on a regular basis; Welcome inspection teams from the Ministry of Environmental Protection, the Environmental Protection Department of the Autonomous Region, the Eastern Supervision Center, Chifeng Environmental Protection Bureau, Chifeng Environmental Monitoring Brigade, Chifeng Environmental Monitoring Station, Banner Government and Banner Organs. Successfully completed the tasks assigned by environmental protection and construction departments at all levels.
Second, the operation of equipment in each workshop of Keqi Sewage Treatment Plant
After five years' operation, Keqi Sewage Treatment Plant suffered from equipment failure and serious wear due to aging, frost heaving in winter, unstable influent quality and excessive sediment. For example, due to the unstable inlet water quality, the instantaneous flow rate is not easy to control, and there are too many sediments and sundries, the grid can not operate normally, which affects the normal and stable operation of the sewage treatment plant and reduces the sewage treatment effect. In order to ensure the sewage to reach the standard stably, our factory has organized personnel to dredge and repair the equipment failures, especially the failure of the water intake grille, the failure of the sewage lifting pump and the failure of the fan. The normal operation of the equipment is ensured. The installed COD online monitoring equipment and ammonia nitrogen online monitoring equipment all passed the comparison and acceptance, and the comparison results met the requirements of relevant laws and regulations, and passed the acceptance of Chifeng Environmental Protection Bureau.
Third, the laboratory.
The water quality laboratory of Keqi Water Supply Company tests the domestic drinking water and sewage according to the company's requirements. * * * Drinking water source wells, factory water of Qingshui Plant and water at the end of pipe network were inspected 58 times; Complete 7 items of sewage self-inspection (water temperature, PH, COD, ammonia nitrogen, SS, dissolved oxygen), and manually supplement the data of sewage online monitoring system after the failure. The test results all meet the national standards.
Four. Progress of bid raising and pipe network expansion project, reclaimed water reuse and sludge treatment project of sewage treatment plant in Hexigten Banner.
The total investment of the upgrading project of the sewage treatment plant in Hexigten Banner is 99.4644 million yuan. 20 14 completed the construction of comprehensive equipment room, comprehensive water production workshop, MBBR pool, composite hydrolysis pool and sludge pump house, and completed cable laying, equipment procurement and installation. Enter the commissioning and operation stage, and complete the environmental protection acceptance before the end of the year.
The reclaimed water reuse and sludge treatment project is planned to complete the preliminary procedures of the project, and the construction is planned to start in September 2065438+2005.
Verb (abbreviation of verb) 20 15 year work plan
According to the operation of equipment in each workshop in 20 14 years, in 20 15 years, our factory plans to carry out professional maintenance on some equipment with long operation time and high failure rate (such as fans, grilles, pumps, etc.); It is planned to clean up the sediment deposited between the intake grille, intake pump house, biofilter and the second pump house twice a year (once in May after the temperature warms up and once in June before winter at 5438+ 10) to ensure the normal operation of the grille and sewage lift pump; Strengthen laboratory management, increase testing items and frequency to ensure experimental quality; Study hard to understand sewage treatment technology, new national standard, new methods and sewage treatment laws and regulations. Strive to improve the professional quality of employees, improve their personal ability, and ensure the stable operation of sewage treatment plants. According to the requirements of the company and the higher authorities, ensure the stable operation of the sewage treatment plant and contribute to the energy saving and emission reduction of Keqi.
20 17 Two people summarized that 20XX was the second year of Guangye Environmental Protection Company's operation. Under the correct leadership of Heyuan Branch, our factory earnestly implemented the production tasks and working ideas issued by the group company and its branches in the past six months, focused on safety production, deepened ideological work, changed work style, and achieved double harvests in economic, environmental and social benefits. The situation in the past six months is reported as follows:
First, the stable operation of sewage plants.
1. Establish the operating parameters of A/A/O process.
The external inflow of our factory has always deviated greatly from the design value, which has affected the cultivation and normal operation of activated sludge in the sewage treatment system. In view of the determination of parameters, we break it down into several aspects: First, the improvement and perfection of the filing report, and the existing filing report is repetitive and insufficient. On the one hand, we should continue to cooperate with the filing requirements of national environmental protection COD emission reduction verification, on the other hand, we should truly and comprehensively reflect the operation of the whole sewage treatment plant, so that the daily data report can reflect the operation of one day. Second: continuity and integrity of laboratory data. Laboratory items will develop steadily with the continuous improvement of the professional level of laboratory personnel. We will gradually adjust an accurate laboratory item list according to the requirements of actual operating parameters, so that laboratory data can fully reflect the process operation. Third, establish a monthly statistical analysis system. For each month's operation parameters, we will form a monthly statistical analysis of parameters and establish a monthly operation file for each month's operation.
Finally, a complete operation file is formed, which provides accurate records and analysis for the determination of operation parameters.
2, the establishment and implementation of the plant equipment operation and maintenance system.
The equipment in our factory has various problems to varying degrees. In order to ensure the good operation of the equipment, we will establish an equipment management system. In this equipment management system, it should cover basic equipment files, spare parts inventory, equipment running time statistics, equipment maintenance statistics, equipment refueling and lubrication records, equipment fault statistics and analysis, equipment maintenance records, equipment running risk assessment and so on. Through the establishment of equipment management system, the stable and low failure rate operation of each set of equipment is finally realized.
Second, realize low-cost operation and maximize profits.
First of all, we should establish a strict financial system and clear financial statements. For the necessary monthly financial expenditure, we should make good use of the money from financial management, so that every sum of money spent can be beneficial, and check what the money spent has done, whether it has achieved the goal, analyze the reasons, sum up and accumulate, realize multi-level control over the use of expenses, and save every sum of money as much as possible from the source. It is also necessary to establish a strict system of checking accounts, cards and materials, strictly manage and use materials inventory, rationally use materials, put an end to waste, especially fragile and consumable materials, and extend the service life of materials as much as possible from manual use, thus reducing material consumption. For the management of tools, it is necessary to establish a detailed personal tool account, clarify the use period of tools and tools, and report the loss. And strengthen the care and use of tools and tools by employees, thus reducing production consumption. In addition to strengthening management in financial management and financial system, we should actively tap the potential of operation structure, ensure operation technically, reduce production energy consumption and drug consumption, realize low-cost operation and create greater economic benefits, especially how to reduce the energy consumption of some major energy-consuming equipment. Formulate detailed technical scheme to realize low-energy operation of high-energy equipment, reduce power consumption and reduce production and operation costs. We will also strengthen management in all aspects, realize low-cost operation from management, reduce management costs by improving management in all links, further reduce costs from orderly and efficient management, and maximize profits.
Third, establish a professional work team.
The employees recruited by our factory have a relatively high foundation, generally with college education or above, and they are all around the age of 25, which can be strongly shaped. Such a workforce is a young team with great potential. We will do relevant work in the training of the working team, and plan to train the team of our factory into a professional working team through one year's training. According to this goal, we will make an annual training plan, especially for the process operation of our factory, establish a complete training plan for all staff, conduct comprehensive and systematic training for all technical links of the sewage treatment plant, and establish a training effect inspection mechanism to test the training effect through written assessment, on-site operation and oral expression. Finally, every employee can understand and operate all the technical links of the sewage treatment plant. Ultimately achieve the goals of each employee? Four understandings and four meetings? That is to understand the basic knowledge of sewage treatment, the function and management methods of buildings in the factory, the distribution and use of pipelines in the factory, the meaning and calculation method of technical and economic indicators, and the significance and application of laboratory indicators; It can distribute gas and sludge reasonably, dispatch air reasonably, return and discharge sludge correctly, and eliminate faults in operation. While training all employees, we will also make different training plans for each employee. According to the different characteristics of each employee, establish an annual development plan for each employee through conversation and communication with employees. By establishing the annual development plan of all employees, the work of sewage treatment plant in 20XX is decomposed into each employee's plan, and the personal growth of employees and the development of sewage treatment plant are organically combined to achieve two good situations. In 20XX, we will also organize related group activities to strengthen the solidarity and mutual assistance among employees, enhance their unity and relationship, and strengthen the cooperation and cohesion of the team, so that every employee can have a sense of belonging and accomplishment, find their own value in their work and establish their own life values.
Fourth, establish a comprehensive safety management system.
As a sewage treatment plant, safe production is an important link. We will achieve safe production in 20XX by establishing a top-down comprehensive safety management system. The established safety management system will include safety management system documents (which have been formulated and need to be improved); Safety knowledge training; Monthly investigation system for potential safety hazards; Weekly safety meeting system; Safety capital investment plan; Procurement and putting-in-service proactively of safety protection articles; The establishment and implementation of weekly safety officer system; The way to implement the workshop safety responsibility to the specific person in charge; The establishment of fire safety system and fire knowledge training, etc. By establishing a complete and comprehensive safety management system, three-level safety management of factories, teams and employees can be realized. Every employee will establish a sense of safety at work, have a safety operation certificate for dangerous operations, strictly implement safety operation procedures at work, have safety inspection and safety tips for each post, and have a safety management summary every month, quarter and year to ensure that there are no accidents in safe production throughout 20XX.
Shortcomings, problems and improvement measures of verb (abbreviation of verb);
1, rules and regulations need to be further strengthened and improved; Team members should take the lead in learning and improving their ideas and professional quality.
2, the lack of daily communication with employees and collaborative teams, to strengthen the daily work communication between team members and employees, can not ignore the communication with employees because of busy work, to fully mobilize the enthusiasm and initiative of all employees.
3. Strengthening employees' awareness of saving, whether the unit benefit is good or bad, and employees' awareness of cost and saving are also a key to controlling costs. In the future work, we should advocate saving glory and wasting shame, advocate new civilization, improve various cost planning systems, plug loopholes, reduce consumption and improve efficiency.
20XX Work Plan for the Second Half of the Year
1, fully understand the great significance of building a harmonious enterprise, strive to build the leading group and employees into organizers of building a harmonious enterprise, and build the leading group into promoters of building a harmonious enterprise.
2. Further improve the system of democratic management and staff openness, and safeguard the political, economic and cultural rights and interests of the broad masses of employees.
3. according to the requirements of the company leaders, grasp every key link, and all the work should be put forward according to the company leaders? Management creates efficiency? Requirements, according to the procedures, strict control, steady progress, and earnestly do all the work.
4, combined with the national safety month activities carried out in June, carry forward the achievements, overcome the shortcomings of the past, make the safety management work to a higher level, and ensure safety and no casualties throughout the year.
In short, we have made remarkable achievements in the past six months, but the existing problems are also very prominent. In the second half of the year, we have the determination, confidence, ability and obligation to build Meixian Guangye Environmental Protection Co., Ltd. into a team with excellent ideological style, unity and harmony, honesty, efficiency and pragmatism, and lay a solid foundation for the economic development and smooth development of Guangye Environmental Protection Group.
20 17 3 personal summary of sewage treatment plant I. general situation of operation
1, process control
From June 5438+0 to February 65438+2, the cumulative domestic sewage treatment plant in our factory is expected to reach132,000 tons, with an average daily treatment capacity of about 36,000 tons and a maximum daily treatment capacity of 44,000 tons. The average influent COD 184mg/L and effluent COD/L are reduced cumulatively. The average influent ammonia nitrogen is 22.5mg/L, and the effluent ammonia nitrogen is 8.3mg/L, which reduces ammonia nitrogen 187 tons. 1-65438+2 months produces 2860 tons of surplus sludge, * * consumes PAM flocculant 1 ton, and the average moisture content of sludge is lower than 80%, of which 2860 tons of surplus sludge has been transported to Yichun municipal solid waste landfill for harmless treatment; During1-65438+February, the total power consumption of the treatment plant was 2.28 million kwh, and the average monthly power consumption was about 1.9 million kwh. The average daily power consumption is 6246 kWh, and the average power consumption per ton is 0. 173 kW/hour/ton.
Our factory overhauled the aeration equipment of the reaction tank from the end of July to the end of August in 20 14. After overhaul, the activated sludge in the reaction tank is lost and reduced to varying degrees, which leads to the decline of biochemical treatment efficiency and the excessive ammonia nitrogen in the effluent. After taking a series of recovery measures, our factory is running stably at present, and the average indexes of effluent quality are as follows: CODcr36mg/L (standard value? 60mg/L), BOD58. 1mg/L (standard value? 20mg/L), SS8mg/L (standard value? 20mg/L), total phosphorus 0.3mg/L (standard value? 1.0mg/L), ammonia nitrogen 4.5mg/L (standard value? 15mg/L), which conforms to the pollutant discharge standard for urban sewage treatment plants (GB 189 18? 2002) National Level B Standard.
2. Equipment operation
Our factory has been in operation for more than 4 years since it was put into production on June 20 10. In order to ensure the safe, efficient, normal and continuous operation of the equipment in the treatment plant, the equipment was overhauled and replaced in all directions this year. In addition to lubricating and maintaining the components according to the equipment manual to prolong the service life of the equipment, the main tasks that have been completed at present include: replacing the lubricating oil and belts of three aeration fans; Replace lubricating oil of three lift pumps and repair check valves; 4 reasoning machine for lubricating oil; Replace the lubricating oil and high-pressure cleaning system in the mud pressing system; Maintain 8 water valves and air valves; 16 maintenance of reflux pump and sludge pump; 3# aeration fan blade replacement; 3# decanter replaces hydraulic screw; Replace the lamp tube, sleeve and ballast of ultraviolet disinfection equipment; Thoroughly overhaul and replace the aeration tray of the biochemical tank; Maintenance and replacement of on-line monitoring equipment (sludge concentration meter, dissolved oxygen meter, liquid level meter) in biochemical pool; Finish the painting and anti-corrosion work of protective railings beside the sewage plant pool; The central control system has been improved. According to the problems in actual operation, our factory gradually improves the operating procedures of equipment and facilities, and trains all employees to ensure the normal operation of facilities and equipment in sewage treatment plant.
3. Laboratory analysis
The laboratory of sewage treatment plant carries out various tests on the inlet and outlet water quality to guide and cooperate with the operation. According to the monitoring results of the laboratory, our factory operated stably from June 5438 to August this year, and the effluent basically reached the standard. In September and June, 5438+ 10, the effluent ammonia nitrogen exceeded the standard in some periods. On the basis of routine water quality testing, the laboratory has increased the detection frequency of ammonia nitrogen in effluent from each pond, providing a basis for process adjustment. Since the end of 10 this year, the effluent has gradually recovered to the standard. At present, all ponds are operating normally, and all pollutants are discharged up to standard. In addition, the laboratory cooperates with the monitoring station of Yichun Environmental Protection Bureau to monitor the water quality of the sewage plant every month; Cooperate with the operation and maintenance personnel of online monitoring equipment to compare and test online monitoring equipment to ensure the accuracy of the equipment; In addition, while doing a good job of daily detection and analysis in the treatment plant, the laboratory also undertakes the report of relevant data.
4. Others
This year, our factory has received 10 many overseas visits and inspections by leading departments at all levels. Every time, we strive to meet the inspection and visit tasks in the best state. We actively rectify the problems raised by leaders at all levels and actively adopt good opinions. On February 2nd this year, Mayor Bai of 65438 Municipal Government, Mayor Lu, Director Zhang of the Park, Director Zheng of the Municipal Environmental Protection Bureau and Director Gao of the District Environmental Protection Bureau led the expert group to inspect the factory. On the basis of listening to the work report of the sewage treatment plant, they made an on-the-spot investigation on the actual operation of our plant, fully affirmed the rectification and operation of our plant, and the expert group also put forward valuable opinions on the operation of our plant.
Second, personnel management
1, personnel training
At present, the sewage treatment plant has a total of employees 18, including 3 managers, 8 operators on duty, 2 laboratory technicians, 2 accountants 1 person, 2 electrical maintenance workers, buyers 1 person and chefs 1 person. This year, combined with the actual operation of the treatment plant, the staff of the whole plant were trained for 6 times in the form of counseling and examination, and the assessment was 1 time. Through a series of training and assessment, on the one hand, the employees of the whole factory can better understand the running process of our factory and the influencing factors that will cause great changes to the process, so as to control various process parameters in time in daily operation; On the other hand, it has also improved the professional technical knowledge and operation level of all employees, laying a good foundation for building a professional sewage treatment plant staff.
2. Control system
Institutionalized and standardized management is the main direction of the development of sewage treatment plants. This year, our factory has formulated and improved a series of rules and regulations, including post responsibility system, safety production management system, handover system, dereliction of duty investigation system, health management system, early meeting system, laboratory management system, canteen management system, duty record filling system and operation report management system. In addition, according to the actual operation situation, we have improved the equipment operation procedures, various reports and production materials. Through the implementation of the above-mentioned series of rules and regulations, the management of our factory has been further improved, laying a solid foundation for the normal operation in the future.
Three. Phase II project construction
1 and the progress of the second phase project
Due to the needs of Yichun city development, the second phase project started by our factory is expected to invest 65 million yuan, mainly to build two CASS pools, a grid room and supporting equipment, pipelines and electrical installation projects. The second phase of the project was officially started on June 20th 1 4th1. Up to now, the accumulated investment is 38 million yuan. At present, the civil construction of two CASS biochemical reaction tanks in the second phase has been completed, and the main project between fine grids has been completed. The rest of the grid decoration is expected to be completed before May 20th next year, the supporting civil parts and equipment installation in the second phase will be completed before May 30th, and all the work will be completed before the end of August, striving for 9.
2. The focus of the current second phase project.
At present, it has entered winter, and the geographical and climatic factors in Yichun are not suitable for continuous construction. At present, the focus of work is the wintering protection of the second phase of civil engineering, laying a good foundation for next year's work. The measures we will implement are:
1, the exterior wall is backfilled with non-expansive materials such as sand and gravel for 2m;
2. Paste 1.2m high insulation board on the inner wall of the tank, and inject 3m deep water into the tank; 24-hour patrol, rest and reduce the internal pressure of ice water on the pool wall.
3. Exposed beams and columns shall be covered with insulation board or insulation cotton for protection.
4. Protective railings and warning signs should be installed around the pool body and wall to strengthen daily management and maintenance.
5. Track the weather changes at any time, take corresponding preventive measures according to the specific situation, strictly implement the wintering plan of our project department, and spend this winter safely and smoothly to the maximum extent.
IV. Working Ideas of 20 15
20 15 is an extraordinary year for Yichun central city sewage treatment plant. Next year, the second phase of the project will be officially put into operation. By then, the daily treatment capacity of the whole sewage treatment plant will reach 654.38+10,000 tons, and the greater the pressure, the greater the power. After the overhaul of the equipment in the whole plant this year, I believe that in the new year, with the care of leaders at all levels in the city and district and the support of company leaders, all our employees will continue to do so. Go all out to complete the tasks and work objectives of the new year, ensure the stable operation of the sewage treatment plant, the normal operation of the equipment and the discharge of the effluent up to the standard, and hand in a satisfactory answer sheet for the sewage treatment cause.